Cement, Lime and Mortar Testing Equipment
Browse cement, lime and mortar laboratory and site testing equipment. View specifications and request a quotation from Impact Test Equipment.
Equipment categories
- 387
- 513
- Aggregates
- Asphalt and Bitumen
- Balances
- Calibration and Measurement
- Cement, Lime and Mortar
- Chemicals
- Concrete
- Environment and Meteorological
- Glass and Plastic Ware
- Miscellaneous Equipment and Hardware
- Mobile Laboratories
- Ovens and Furnaces
- Rock
- Sieving
- Soil and Geotechnical
- Steel Testing
- Test Chambers
- Test Sets to International Standards
- Thermometers, Probes and Thermocouples
Products (87)
- Cube Mould, 70.7mm BS 4550 (CE265) — Steel, complete with baseplate to BS 4550 3 moulds required for test
- Curing Cabinet to EN196-1 (CE219) — with digital thermostat and 3 shelves, 230V 50/60Hz For curing mortar and cement specimens at controlled humidity and temperature. Both external and internal wa
- Dewar Vessel - Reactivity Test (CE221) — spare for CE220 Reactivity Test Apparatus Dewar vase 1L D.77mm openable Dim: 12.5x12.5x31.5cm
- Dropping Ball - Ball Penetration Measuring Device (CE131) — for CE130 Dropping Ball Apparatus Picture shows Ball Penetration Measuring Device CE131 with Dropping ball apparatus CE130, which is available separately.
- Dropping Ball Apparatus (CE130) — with stand, ball and mould to BS 4551-1, BS 6463-4 Dropping ball apparatus to BS 4551-1, BS 6463-4 Used to measure the consistency of cement mortars, this allow
- Extensibility of Mould Apparatus (CE305) — for use with CE300 Le Chatelier Mould Used to check the elasticity of the split cylinder of the Le Chatelier Mould. Complete with 300g weight.
- Filter Papers grade 904 for Water Retention (CE148) — 150mm x 175mm, pack of 100
- Final Set Needle 1.13mm diameter to EN/BS (CE123) — for use with CE350 to EN 196-3:2005, BS 4550
- Final Set Needle to EN196-3 (CE106) — 1.13mm diameter to EN/BS for use with CE100 chrome plated mild steel, all dimensions in mm
- Fineness of Fly Ash (CE182) — wet sieving set to EN 451-2, ASTM C430 The set consists of a 50mm diameter sieve with 0.045mm aperture stainless steel mesh, 17.5mm internal diameter spray nozz
- Flexural Device to EN196/01 (CE450) — for 40.1mm x 40mm x 160mm prisms to EN 196-01, NF P15-451, DIN 1164, EN ISO 679 This device is designed for a perfect fit between compression machine or flexura
- Flow Channel Test Apparatus - CE174 (CE174) — Mild Steel. The Flow Channel Test Apparatus is designed to determine the consistency and expansion characteristics of premixed cement mortars for anchorages whe
- Flow Cone (CE165) — to ASTM C939 method for the determination of the time of eflux of a specified volume of fluid hydraulic cement grout through a standardised cone.
- Flow Cone (Cast Aluminium) (CE163) — to ASTM C939 Cast-aluminium flow cone with either 13mm or 19mm replaceable orifice. The flow cone includes an adjustable point gauge assembly. Overall dimension
- Flow Cone Stand - CE166 (CE166) — For use with flow cones CE165 and CE168. The Flow Cone Stand is a robust laboratory support stand designed to securely hold and position a flow cone apparatus d
- Flow Table Replacement Conical Mould (CE150/1) — for CE150 flow table
- Flow Table to BS and ASTM (CE150) — complete with base The flow table consists of a machined table top with spindle, mounted on a cast iron tripod with a horizontal shaft carrying a cam at one end
- Flow Trough 1140mm Long (CE553) — for the Colcrete Flow Trough Test Used to determine and maintain the fluidity of the grout at the mixer. Its use ensures that the grout is of the correct consis
- Flow Trough 826mm Long (CE552) — for the Colcrete Flow Trough Test Used to determine and maintain the fluidity of the grout at the mixer. Its use ensures that the grout is of the correct consis
- Fluidity Cone (CE168) — to EN445 Used for testing the fluidity of grout. Conforms to EN445
- Gillmore Apparatus (CE135) — to ASTM C91, ASTM C141, ASTM C266, AASHTO T154 The Gillmore Apparatus is used to determine the setting time of cement. The vertical support shaft has a device t
- Hand Operated Flow Table with 300mm diameter stainless steel top, to EN1015-3 (CE152) — supplied complete with conical mould and tamper.
- Insulated Dewar Flask (CE212) — Spare for Heat of Hydration Apparatus.
- Jolting Table for prism compaction (CE230) — for use with 3 gang mould CE240 to EN 196-1, EN ISO 679, BS 3892, UNE 80101/ NF P15-412 Used to compact 40mm x 40mm x 160mm cement mortar prisms in the three ga